Setting The Fuser Control Temperature - Kyocera TASKalfa 6501i Service Manual

Hide thumbs Also See for TASKalfa 6501i:
Table of Contents

Advertisement

Item No.
U161

Setting the fuser control temperature

Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper,
or solve a fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
Warm Up
Print
Low Power Mode
Belt Mode
Ready Time Adjust
Setting: [Warm Up]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
Display
Ready
(Center)
Ready
(Edge)
Ready
(Press)
Drive
(Center)
Wait
(Center)
Low Power
(Press)
Full Speed
Shift(Center)
Pressure
(Press)
3. Press the start key. The value is set.
Display
Control temperature except at printing
Control temperature during printing
Heating power reduction control
Settings against broken fusing belt control
Setting the Temperature to Activate Aging
Description
Control temperature at dis-
playing Ready (Center)
Control temperature at dis-
playing Ready (Edge)
Control temperature at dis-
playing Ready (Press)
Stable temperature during
driving (Center)
Stable temperature during
halt (Center)
Control temperature at low
power consumption
(Press)
Full speed shift tempera-
ture (Center)
Pressurizing beginning
temperature (Press)
Description
Description
Setting
range
130 to 200
165
(°C)
100 to 200
140
(°C)
0 to 200
30
(°C)
130 to 200
170
(°C)
130 to 200
165
(°C)
0 to 200
130
(°C)
0 to 200
50
(°C)
0 to 200
150
(°C)
1-3-92
Initial setting
65ppm
80ppm
165
140
30
175
170
130
50
155
2N8/2N7