item No.

Checking/clearing the fuser counts

U167
Description
Displays and clears the fuser counts for checking.
Purpose
To check the fuser count after replacement of the fuser unit. Also to clear the counts after replacing unit.
Method
1. Press the start key. The fuser counts is displayed.
Clearing
1. Select [CLEAR].
2. Press the start key. The count is cleared.
Setting
1. Change the count using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.

Setting the fuser drive control

U193
Description
Specifies ON/OFF the fuser drive control.
Purpose
Countermeasure against black dots which is caused by toner adhering to the heat roller separation claws.
Setting
1. Press the start key.
2. Select ON or OFF.
Display
ON
OFF
Initial setting: ON
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.