Setting The Fuser Control Temperature - Kyocera FS-C8520MFP Service Manual

Hide thumbs Also See for FS-C8520MFP:
Table of Contents

Advertisement

Item No.
U161

Setting the fuser control temperature

Description
Changes the fuser control temperature and control temperature correction value and other set
values.
Purpose
Normally no change is necessary. However, this mode can be used to prevent curling or creasing
of paper, or solve a fuser problem on thick paper.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor left/right keys.
Display
Copy
Curb(Edge)
Curb(Edge)
Return(Edge)
Ready(Edge)
Pressure(Press)
High
speed(Center)
Ready(Center)
Drive(Center)
Full speed(Cen-
ter)
Wait(Center)
WarmUp
Curb(Center)
Curb(Center)
Low power(Cen-
ter)
Ready(Press)
Curb(Press)
Wait Off-
set(Press)
4. Press the start key. The value is set.
Description
Description
Prevention temperature of overtem-
perature rise under copy
Prevention temperature of overtem-
perature rise
Return temperature of overtempera-
ture rise
Ready display temperature
Pressurizing beginning temperature
Full speed shift temperature
Ready display temperature
The second stability temperature
Print control temperature
Control temperature when being
standing by
Electric power control temperature
at start-up
Prevention temperature of overtem-
perature rise
Low electric power control
temperature
Ready display temperature
Prevention temperature of overtem-
perature rise
Correction temperature when being
standing by
1-3-61
Setting
Initial
range
setting
20ppm 25ppm
100 to 250
210
100 to 250
240
100 to 250
190
0 to 200
95
0 to 200
85
0 to 200
110
100 to 200
135
100 to 200
140
100 to 200
140
100 to 200
115
0 to 200
135
170 to 250
240
0 to 200
85
0 to 200
40
170 to 250
200
0 to 200
85
2MY/2MZ
210
240
190
100
90
115
140
145
145
120
140
240
90
45
200
90