Kyocera TASKalfa 300i Service Manual page 176

Hide thumbs Also See for TASKalfa 300i:
Table of Contents

Advertisement

2K5
Code
C8350
Roller motor problem (optional docu-
ment finisher)
The roller sensor does not turn on/off
within specified time of the roller motor
turning on.
C8360
Slide motor problem (optional docu-
ment finisher)
The slide sensor does not turn on/off
within specified time of the slide motor
turning on.
C8440
Sensor adjusting problem (optional
document finisher)
The sensor cannot be adjusted within
the specified range.
C8460
EEPROM problem (optional document
finisher)
Reading from or writing to EEPROM
cannot be performed.
C8800
Document finisher communication
error (optional 3000-sheet document
finisher)
A communication error from document
finisher is detected 10 times in succes-
sion.
1-4-32
Contents
Causes
Check procedures/corrective measures
The roller sensor,
Reinsert the connector. Also check for conti-
roller motor con-
nuity within the connector cable. If none,
nector makes poor
remedy or replace the cable.
contact.
Defective roller
Replace the roller sensor.
sensor.
Defective roller
Replace the roller motor.
motor.
Defective finisher
Replace the finisher main PWB and check
main PWB.
for correct operation.
The slide sensor,
Reinsert the connector. Also check for conti-
slide motor con-
nuity within the connector cable. If none,
nector makes poor
remedy or replace the cable.
contact.
Defective slide
Replace the slide sensor.
sensor.
Defective slide
Replace the slide motor.
motor.
Defective finisher
Replace the finisher main PWB and check
main PWB.
for correct operation.
The paper entry
Reinsert the connector. Also check for conti-
sensor connector
nuity within the connector cable. If none,
makes poor con-
remedy or replace the cable.
tact.
Defective paper
Replace the paper entry sensor and check
entry sensor.
for correct operation.
The optical path of
Remove the foreign matter.
the paper entry
sensor is blocked
by foreign matter.
Defective finisher
Replace the finisher main PWB and check
main PWB.
for correct operation.
Defective
Replace the finisher main PWB and check
EEPROM or fin-
for correct operation.
isher main PWB.
Poor contact in the
Check the connection of connector on the
connector termi-
engine PWB and the connector on the fin-
nals.
isher main PWB, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective PWB.
Replace the finisher main PWB or engine
PWB and check for correct operation.
Remarks

Advertisement

Table of Contents