2K5
26. Remove the bush and cam.
27. Remove the stop ring.
28. Slide the MP forwarding pulley with the for-
warding pulley retainer from the shaft to
remove it.
29. Replace the MP separation, MP paper feed
and MP forwarding pulleys.
30. Refit all the removed parts.
When refitting the MP unit cover, the films
on the cover are positioned under the MP
paper feed pulley shaft.
31. When the MP forwarding pulley, MP paper
feed pulley or the MP separation pulley is
replaced, perform maintenance mode U901
to clear the counter value (see page 1-3-84).
1-5-14
Bush
Cam
Stop ring
MP forwarding
pulley shaft
Film
MP paper feed
pulley shaft
MP forwarding
pulley
Bush
MP forwarding
pulley retainer
MP forwarding pulley
MP forwarding
pulley retainer
Figure 1-5-25
MP unit cover
Film
Figure 1-5-26