Connector
Pin No.
YC6
1
Connected
2
to the home
3
position
4
switch, origi-
nal detec-
5
tion switch
6
and original
7
size sensor
8
9
YC7
1
Connected
2
to the
3
optional DP
4
YC8
1
Connected
2
to the
3
optional DP
4
5
6
7
8
9
10
YC9
1
Connected
2
to the power
source PWB
Signal
I/O
+5VSL
O
HPSWN
I
GND
-
+5VSL
O
OPSWN
I
GND
-
+5VSL
O
ORGLSWN
I
GND
-
+24VSL
O
GND
-
+5VSL
O
GND
-
GND
-
GND
-
GND
-
GND
-
ORGVSYNC
I
DP_RDY
I
DP_SEL
O
SCLK
O
SDO
O
SDI
I
+24VSL
I
GND
-
Voltage
5 V DC
5 V DC power output to HPSW
0/5 V DC
HPSW: On/Off
-
Ground
5 V DC
5 V DC power output to ODSW
0/5 V DC
ODSW: On/Off
-
Ground
5 V DC
5 V DC power output to OSS
0/5 V DC
OSS: On/Off
-
Ground
24 V DC
24 V DC power output to DP
-
Ground
5 V DC
5 V DC power output to DP
-
Ground
-
Ground
-
Ground
-
Ground
-
Ground
0/5 V DC
Original scanning interval signal
0/5 V DC
DP ready signal
0/5 V DC
DP select signal
0/5 V DC (pulse)
DP clock signal
0/5 V DC (pulse)
DP serial communication data signal
0/5 V DC (pulse)
DP serial communication data signal
24 V DC
24 V DC power input from PSPWB
-
Ground