Mode; Mode / Multi Mode Setting Method - Konica Minolta 7155 Service Manual

Hide thumbs Also See for 7155:
Table of Contents

Advertisement

47 MODE

47 MODE

[1] 47 Mode / Multi Mode Setting Method

1. 47 Mode
This mode provides self-diagnostic functions
(input/output check function) to check and adjust
various signals and loads.
2. 47 mode operation
(1) Starting 47 mode
a.
Turn off the SW2 (sub power).
b.
Turn the SW2 back on while holding down 4 and
7 of the copy quantity button.
c.
Check that the 47 mode is started when message
"I/O check mode" appears in the first row of the
message area.
(2) Input/output check
a.
Use the copy quantity button to enter the code
(Refer to the I/O check code list.) for the desired
signal sources (such as sensors).
b.
The entered code appears enclosed in <> in the
second row of the message area.
c.
The numbers are shifted left as they are dis-
played.
d.
Check the status of the signal displayed as H or L
after "IN:" in the second row of the message dis-
play area.
Caution: H and L indicate the level of the signal
input to PRCB (printer control board).
Note the relationship between the sta-
tus of the input signal source and the
message display.
(3) Output check
a.
Use the copy quantity button to enter the code
(Refer to the I/O check code list.) for the desired
output load.
b.
Press the Start button.
Depending on the output, a load will be activated
or a signal will be output.
Start button
Before pressing
indication
After pressing
Code
Description
Input
Input signal level
Output load opera-
Output
tion/signal
(4) Ending 47 mode
a.
Press the stop button to cancel the operation.
b.
Turn off the main switch to exit the 47 mode.
Step
Turn on the SW2 (sub power) while hold-
ing down 4 and 7 of the copy quantity
1
button.
[I/O check Screen]
Use the copy quantity button to enter the
2
code.
Check the input signal check result dis-
played after "IN:" in the second row of
3
the message area.
To perform the output check, press the
4
Start button to check the output load.
Press the Stop button to end output
5
check.
To perform other checks, enter a new
6
code using the copy quantity button.
Turn off the main switch to exit the 47
7
mode.
Note1: No data appears on the second row of
the message area when 47 mode is
entered. Message appears when a num-
ber is entered.
Note2: Simply enter a new code to switch to
another code.
Note3: A newly entered number is written over
the previously entered number.
1-84
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: