Cleaning The Slit Glass And Platen Glass; Replacing The Scanner Motor (M11) - Konica Minolta 7155 Service Manual

Hide thumbs Also See for 7155:
Table of Contents

Advertisement

SCANNER SECTION
[6] Cleaning the Slit Glass and Platen
Glass
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
(1) Remove the original stopper plates (left and
rear), platen glass, and top cover (right, left, front
center, and rear center). (See "EXTERNAL SEC-
TION.")
(2) Remove two screws to detach the slit glass.
(3) Place the removed slit glass and platen glass on
a rag and clean with drum cleaner and cleaning
pad.
Screw
Slit glass
Slit glass
(4) Reinstall the above parts following the removal
steps in reverse.
MODEL
7155/7165
SERVICE HANDBOOK
Screw
MANUAL
REVISED EDITION

[7] Replacing the Scanner Motor (M11)

Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Remove the RADF unit, original stopper plates
(left and rear), platen glass, and top cover (right,
left, front center, and rear center). (See "EXTER-
NAL SECTION.")
(2) Remove one connector (CN639) from the APS
timing PS (PS51).
Connector(CN639)
(3) Remove the hinge mounting plate (rear side)
from the scanner unit. (12 screws)
(4) Remove four screws from the scanner motor
(M11), then remove the scanner belt and the
scanner motor.
DATE
PAGE
Nov. 2001
3-C-6
METHOD
REPLACEMENT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

716572557272