[5] Drum Peculiarity Adjustment
(Manual)
1. Maxiumum density manual adjustment
4
This adjustment must be performed under the
guidance of the authorized distributor.
Variable range: 0 to 41
2. Dot diameter manual adjustment
4
This adjustment must be performed under the
guidance of the authorized distributor.
Variable range: 0 to 255
MODEL
7155/7165/7255/7272
MANUAL
REVISED EDITION
SERVICE MANUAL
[6] User Paper Setting
This adjustment is only performed when the user uses
special copy paper and can not be adjusted using the
standard adjustment process.
This setting is applied when "User" is selected for
"Paper type/Special size setting" in the key operator
mode or when "User paper" is selected for "Transfer/
separation output for plain paper" or "recycled paper"
in 25 mode DIPSW.
The data for 16 lb. plain paper" is input as the default.
Step
Enter the 36 mode.
1
[Adjustment mode menu Screen]
2
Press "
[Process adjustment mode menu
Screen]
3
Select "
Transfer/separation output screen
appears.
Enter data according to the user speci-
4
fied paper. Data should be input under
the guidance of the authorized distribu-
tor.
DATE
1-55
Dec. 2003
4
36 MODE
Operation
Process adjustment".
1
User paper setting".