Replacing The Exposure Lamp - Konica Minolta 7155 Service Manual

Hide thumbs Also See for 7155:
Table of Contents

Advertisement

SCANNER SECTION
(4) Remove two screws to remove the CCD unit.
Marking
Caution: Mark the place where the CCD unit is
installed before removing it.
(5) Reinstall the above parts following the removal
steps in reverse.
Screws
CCD unit
Marking
3-C-2
3-C-4

[3] Replacing the Exposure Lamp

Caution1:
Be sure the power cord has been
unplugged from the wall outlet.
Caution2:
Do not touch the exposure lamp with bare
hands.
Caution: Be sure to check the image after
installing the exposure lamp. (See
"ADJUSTMENTS.")
a.
Procedure
(1) Remove the original stopper plates (left and
rear), platen glass and top cover (right, middle
front, and middle rear). (See "EXTERNAL SEC-
TION.")
(2) Move the exposure unit to the notch in the main
body frame on the paper exit side.
(3) Remove the connector and two screws, then
remove the exposure lamp.
Connector
Exposure lamp
(4) Reinstall the above parts following the removal
steps in reverse.
Screw
Exposure lamp
Screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

716572557272

Table of Contents