36 MODE
9. Auto gamma adjustment (2 dot)
Performs gamma adjustment (2 dot) automatically.
This adjustment should be performed when the drum,
developer, write unit, or dust-proof glass is replaced.
Preparation: Be sure the drum unit is set.
Auto maximum density adjust-
ment, auto dot diameter adjust-
ment, LD1 offset adjustment , LD2
offset adjustment, and auto
gamma adjustment (1 dot) must
have been completed.
Step
Enter the 36 mode.
1
[Adjustment mode menu Screen]
2
Press "
Process adjustment".
1
[Process adjustment mode menu
Screen]
3
Press "
Drum peculiarity adjust-
2
ment".
[Drum peculiarity adjustment mode
menu Screen]
4
Press "
Auto gamma adjustment
9
(2 dot)".
[Auto gamma adjustment (2 dot)
Screen]
Press the
Start
The drum and developer operate to
5
automatically adjust Gamma.
Adjustment completes in about 10 sec-
onds and an complete message is dis-
played.
Press the
RETURN
6
the Drum peculiarity adjustment mode
menu Screen.
Reference:
If any one of the following error messages
appears during auto gamma adjustment,
clean the TSCB (toner control sensor board),
check its installation state, and retry the auto
gamma adjustment.
γ
<1>Error 1: The
been corrected.
<2>Error 2: No signal is output from the
sor. No control patch is output.
MODEL
7155/7165
SERVICE HANDBOOK
Operation
key.
key to return to
sensor dirt correction has
γ
sen-
MANUAL
REVISED EDITION
<3>Error 3: A recurrence error occurred dur-
γ
ing
curve calculation.
10. Cartridge set mode
This adjustment should be performed when
black dots appears on the copy after the drum
removing and installing.
Step
Enter the 36 mode.
1
[Adjustment mode menu Screen]
2
Press "
Process adjustment".
1
[Process adjustment mode menu
Screen]
3
Press "
Drum peculiarity adjust-
2
ment".
[Drum peculiarity adjustment mode
menu Screen]
4
Press "
Cartridge set mode".
10
[Cartridge set mode Screen]
5
Press the
Start
The developing unit and the drum rotate
for two mintes, and return to Cartridge
6
set mode Screen.
Press the
7
COPY SCREEN
Select the wide paper (ie A3, A4, 11x17,
8.5x11) in the direction of the drum shaft,
8
set 10 copies, and press START button.
If black dots still appear, press the C but-
ton while pressing the P button to return
9
to the cartridge set mode, and repeat the
step 5 to 8.
Press the C button while pressing P but-
10
ton when black dots disappear.
Press
RETURN
11
Drum peculiarity adjustment mode
menu Screen.
DATE
PAGE
Nov. 2001
1-54
Operation
key.
key.
key to return to the
METHOD