Clock; Cluster-Cli - Motorola WS5100 Series Cli Reference Manual

Hide thumbs Also See for WS5100 Series:
Table of Contents

Advertisement

4-10
WS5100 Series Switch CLI Reference Guide
WS5100#clear arp-cache
WS5100#
WS5100#clear logging
WS5100#
WS5100#clear mobility event-log peer
WS5100#
WS5100#clear ip dhcp binding *
WS5100#

4.1.6 clock

Priv Exec Command
Configures the software system clock
Syntax
clock set HH:MM:SS [1-31] MONTH [1993-2035]
Parameters
set
Example
WS5100#clock set 15:10:30 25 May 2007
WS5100#show clock
May 25 15:10:31 UTC 2007

4.1.7 cluster-cli

Priv Exec Command
Use this command to access the cluster-cli context. The cluster-cli context provides
centralized management to configure all members of cluster from one member. Any
command executed under this context is executed to all switches in the cluster.
A new context (redundancy) is available to support the cluster-cli. Any commands
executed under this context are executed on each cluster member.
Use
no cluster-cli
Syntax
cluster-cli enable
Sets system date and time
to exit the cluster-cli context.