Centronics (Parallel) Submenu - Printronix N7000 H-Series User Manual

Cartridge ribbon printer
Table of Contents

Advertisement

Centronics (Parallel) Submenu

Centronics
(from page 66)
Data Bit 8
PI Ignored
Enable*
Enable*
Disable
Disable
Prime
TOF Action
Signal
Enable*
Reset*
Disable
Do Nothing
Data Bit 8
Enable (default). Allows access to the extended ASCII character set.
Disable. The printer interprets bit 8 of each incoming data character as a
zero, regardless of its actual setting.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper motion.
Enable (default). Ignores the PI signal and treats the data as characters
or control codes.
Disable. Causes the printer to interpret the eight data lines as VFU
commands when the PI signal is true.
Data Polarity
The Data Polarity parameter must be set to match the data polarity of your
host computer.
Standard (default). Does not expect the host computer to invert the data.
Inverted. Expects the data received on the data lines from the host
computer to be inverted. Ones become zeros, and vice versa.
Data
Resp.
Polarity
Polarity
Standard*
Standard*
Inverted
Inverted
Buffer Size
Auto
1
in K
Trickle
16*
Disable*
(1-16)
Enable
Centronics (Parallel) Submenu
* = Factory Default
1
H-Series have an extended range to 256
and the default is 64.
Busy On
Latch
Strobe
Data On
Enable*
Leading*
Disable
Trailing
Trickle
Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off