Barcode Options

The following sub-options help define specific options regarding barcode
printing.
UPC Descenders
This parameter allows you to print barcode descenders when human
readable data is not present in the UPC/EAN barcodes.
Always (default). UPC/EAN barcodes are printed with descenders, even
if there is no human readable data.
Never. UPC/EAN barcodes are printed without descenders if there is no
human readable data.
Only with PDF. UPC/EAN barcodes are printed with descenders only
when the PDF command is present.
Optimized Ratio
This option selects different barcode ratios for certain barcodes including
Code 39 and I-2/5. It is included for compatibility with the IGP-X00 printers.
Disable (default). Use standard barcode ratios.
Enable. Select the alternate barcode ratios.
I-2/5 Selection
This option is added to be compatible with a special IGP-X00 customization.
Usually, if I-2/5 barcodes have an odd number of digits, a leading zero is
inserted in front of the data. However, this special IGP-X00 customization
gives you the option of adding a space character at the end of the barcode
instead.
Leading Zero (default). A leading zero is inserted in front of the printable
data field.
Trailing Space. A space is inserted at the end of the printable data field
and a zero is encoded with the corresponding space in the end of the
barcode.
X2 DPD. When selected, an I-2/5 barcode with an X2 magnification will
use the specially configured ratios 3:3:6:5 rather than 3:6:9:12 for
compatibility issues.
Modulo 7 CD. The I-2/5 barcode uses a modulo 7 check digit instead of
the default modulo 10 check digit.
AI 00 Spaces
This option is designated for EAN/UCC-128 barcodes whose application
identifier (AI) is 00.
Disable (default). The printable data field is printed with the AI enclosed
in parentheses. This is the standard EAN/UCC-128 format.
Enable. The printable data field is printed with the UCC fields separated
by spaces. This option is IGP-X00 compatible.