Printronix N7000 H-Series User Manual page 142

Cartridge ribbon printer
Table of Contents

Advertisement

Chapter
4
IGP/VGL Emulation
Ignore CH#1
Specifies character 1 for the character filtering option. Valid decimal values
are from 0 through 255.
Ignore CH#2
Specifies character 2 for the character filtering option. Valid decimal values
are from 0 through 255.
Data Bit 8
Enable (default). The PI line is not passed directly from host to printer; all
8 bits are used for data bits, and characters in the hex 80-FF range can
be accessed.
Disable. When the host PI line is enabled, Data Bit 8 internally indicates
PI line status. To use the PI line, disable Data Bit 8, and enable the Host
PI configuration option (under the PI Control option, below).
NOTE: Data Bit 8 is interpreted as either Data Bit 8 or PI signal, but never
Font Set
The Font Set specifies which language is currently selected for use with the
VGL. Refer to "IGP/VGL Font Set Menu" on page 144 for available selections.
PI Control
Printer PI
Disable (default). The ASCII emulation is configured with the PI line
disabled.
Enable. The ASCII emulation is configured with the PI line enabled.
Host PI
Disable (default). The host does not send PI signals.
Enable. The host sends PI signals. The Data Bit 8 configuration option
must be disabled to transmit the PI line to the printer.
142
both. When enabled as Data Bit 8, Data Bit 8 has priority over the PI
signal, and all data above hex 7F is used to access character data
and not to interpret PI line data.
Conversely, when Data Bit 8 is disabled and the PI signal is used,
Data Bit 8 of the data is reserved for use as the PI function, and you
cannot access characters in the hex 80-FF range. Therefore, to
access characters in the hex 80-FF range, Data Bit 8 must be
enabled.

Advertisement