Installation Location

Choose a location that meets the following criteria:
Note:
SSL1016 Tape Autoloader Reference Guide
Documentation CD (documents in PDF format)
To prevent damage to the tapes and the tape drives, position the
Caution:
autoloader so that no cooling vents are located directly in front of the unit; this
helps minimize the amount of foreign debris entering the tape path.
Room temperature: 10ºC to 35ºC (50ºF to 95ºF)
Power source:
— AC power voltage: 100 V to 127 V or 200 V to 240 V
— Line frequency: 50 Hz to 60 Hz
Air quality: Minimal sources of particulate contamination. Avoid areas near
frequently used doors and walkways, stacks of supplies that collect dust, and
smoke filled rooms. Avoid placing the autoloader near printing machines as
airborne ink contaminates tape drives.
Excessive dust and debris can damage tapes and tape drives.
Humidity: 20% to 80% relative humidity (non-condensing)
Front Clearance: about 2 inches (about 5 cm) from rack door; about 6 inches
(about 15 cm) from wall or solid object; about 12 inches (about 30 cm) to
insert a cartridge in the mailslot, and about 28 inches (about 71 cm) to insert
or remove a magazine.