HP STORAGEWORKS SSL1016 Reference Manual page 128

Tape autoloader
Hide thumbs Also See for STORAGEWORKS SSL1016:
Table of Contents

Advertisement

Troubleshooting
Table 13: Suggested Actions for Operational Problems
Real Time Clock keeps
getting reset/cleared.
128
Problem
Backup server isn't
capable of sending
data to the drive fast
enough.
Network issues.
SCSI issues.
Backup software isn't
configured optimally.
Data set is impairing
performance.
The DLT1 and SDLT
autoloader versions
cannot maintain the
clock when power is off.
Probable Cause
SSL1016 Tape Autoloader Reference Guide
Suggested Action
For the SDLT and Ultrium
drives, the backup server
needs to have lots of memory,
processing power, a
dedicated SCSI bus and a fast
file system.
Most networks aren't capable
of sending data fast enough
to the SDLT and Ultrium
drives. Therefore multiple
network streams of data must
be used for backups
(concurrency.) Also look for
high network traffic, which
can affect backup/restore
performance.
Check termination, and cable
length. Use LVDS SCSI and
don't connect any
Single-Ended devices or
terminators on the same bus
as the autoloader. Ultra 160
is recommended for Ultrium 2
performance.
Make sure that the backup
software is configured for the
best performance. (Block size
at 64 and turn software
compression off).
The following can lower
performance: lots of small
(<64k) files, fragmentation,
and uncompressible data.
Since the DLT1 and SDLT
versions can not maintain
power to the clock when
power is off or the autoloader
is reset, it is recommended to
configure these autoloaders to
connect to a time server
instead of manually setting
the clock.