Table 14: Error Messages
Error Message
00 - 25
26
27
28
29
SSL1016 Tape Autoloader Reference Guide
Description
General software
flags
Message Send ID
error
Message bad
Message parameter
bad
Invalid element
Suggested Repair
Power cycle the autoloader and run the Health test.
Check HP website for firmware updates.
Check SCSI Bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
Check SCSI bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
Check host device driver.
Make sure the software application is supported,
has the autoloader correctly configured, and has
the latest patches installed.
Check SCSI bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
Check host device driver.
Make sure the software application is supported,
has the autoloader correctly configured, and has
the latest patches installed.
Power cycle autoloader. Repeat checks after power
cycle.