Advertisement

Troubleshooting
Table 14: Error Messages
Error Message
2A
2B-2F
30
31 - 38
39
3A
3B
132
Description
Invalid element status
Firmware tables and
stacks invalid
Post Failure
System Monitoring
type events
Offline
Door locked
Open front
Suggested Repair
Check host device driver.
Make sure the software application is supported,
has the autoloader correctly configured, and has
the latest patches installed.
Power cycle autoloader. Repeat checks after power
cycle.
Power cycle the autoloader and run the Health test.
Update firmware.
Change position of the firmware jumper to enable
secondary firmware image:
1. Remove the DCA. (See Appendix D for
instructions.)
2. Change the jumpers on the front of the DCA
from vertical to horizontal or horizontal to
vertical.
3. Install the DCA.
4. Power on the autoloader and, if necessary,
attempt a firmware upgrade.
Verify that the DCA and magazines are properly
seated.
Power cycle the autoloader.
Power cycle the autoloader and run the Health test.
Check HP website for firmware updates.
No action required.
No action required.
Install magazine or magazine blank.
Try a different magazine or magazine blank.
SSL1016 Tape Autoloader Reference Guide