After Load cartridge appears on the LCD, a countdown appears. You have 20
seconds to load a cartridge through the mailslot before it relocks. The autoloader
automatically loads the cartridge into the selected slot.

Moving a Single Cartridge

To move a single cartridge from one location to another inside the autoloader:
1. On the main menu, scroll to Commands.
2. Press Enter.
3. On the Commands submenu, scroll to Move.
4. Press Enter.
5. Under From:, scroll to the current location of the cartridge you want to move.
Note:
a different location.
6. Press Enter.
7. Under To:, scroll to the location to which you want to move the cartridge.
Note:
LCD. Choose a different location.
8. Press Enter.
9. Press Enter.
SSL1016 Tape Autoloader Reference Guide
The Move screen appears.
Occupied slots are indicated by an asterisk.
If you select an empty location No Source Element appears on the LCD. Choose
Occupied slots are indicated by an asterisk.
If you select a location that is already occupied Destination Full appears on the
The LCD displays Ent or Esc? below your selections.
An hourglass appears on the LCD as the autoloader moves the cartridge to its
new location.
Autoloader Operation
79