Nortel Meridian Meridian 1 Feature Description And Administration page 1506

International isdn primary rate interface
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Page 1506 of 1814
Figure 141
Private network to Public network hop off, prior functionality for UDP dialing
originating node A
HLOC = 338
HNPA = 416
HNXX = 253
A
CLID transported is
Digits outpulsed are
DN 2020
Number dialed is
AC1 - 656-4020
Note: the dashes used between the digits in the CLID
are used here to clarify the information.
553-2901-301 Standard 9.00 January 2002
Private to Public CLID Conversion
tandem node B
HLOC = 655
HNPA= 408
HNXX = 565
LDN = 3000
MCDN
B
H338-2020
656-4020
In the example in Figure 141, the calling party dialed a private number in the
UDP format: LOC+DN (656-4020). The originator's DN is 2020 and the
LOC is 338. If the call is routed all the way through the private network, the
user on DN 4020 sees H3382020 on the display. (The terminating node
inserts the letter H in front of the CLID digits to indicate that the call
originated from the private network.)
MCDN TIE trunks busy
CLID sent out is
338-2020
PSTN
Digits
outpulsed
are
16507854020
terminating node C
HLOC = 656
HNPA = 650
HNXX = 785
CO
DN 4020
CLID displayed is
408-338-2020
C