Omron CP - PROGRAMMING MANUAL 05-2007 Programming Manual page 620

Cp1h/cp1l cpu unit
Table of Contents

Advertisement

Table Data Processing Instructions
Variations
Applicable Program Areas
Operands
Operand Specifications
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Block program areas
OK
OK
N: Number of words
N specifies the number of words in the range and must be 0001 to FFFF
hexadecimal (or &1 to &65,535).
R1: First word in range
R1 specifies the first word in the range.
Leftmost byte Rightmost byte
15
8 7
R1
to
R1+(N–1)
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
Indirect DM addresses
in binary
Indirect DM addresses
in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
Step program areas
Subroutines
OK
0
N
CIO 0 to CIO 6143
W0 to W511
H0 to H511
A0 to A959
T0000 to T4095
C0000 to C4095
D0 to D32767
@ D0 to @ D32767
*D0 to *D32767
#0001 to #FFFF (binary) or
&1 to &65,535
DR0 to DR15
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Section 3-16
SWAP(637)
@SWAP(637)
Not supported.
Interrupt tasks
OK
R1
A448 to A959
---
---
587