Omron CP - PROGRAMMING MANUAL 05-2007 Programming Manual page 841

Cp1h/cp1l cpu unit
Table of Contents

Advertisement

Serial Communications Instructions
Operand Specifications
Description
808
R
The m words of data that is
to
received is stored here.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
Indirect DM addresses
in binary
Indirect DM addresses
in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
PMCR(260) will execute the communications sequence specified in C2 using
the logical port specified in bits 12 to 15 of C1 and the physical port specified
in bits 8 to 11 of C1 for the unit address specified in bits 0 to 7 of C1.
If a symbol is specified as the operand for a send message, the number of
send words specified in S and beginning from S+1 will be used as the send
area. If a symbol is specified as the operand for a receive message, receive
data is placed in memory staring with R+1 and the number of words received
is automatically written to R if the transmission is successful.
If the transmission fails, the data (R+1 onward) set before PMCR(260) was
executed will be read from the receive buffer and stored in the R+1 onward
again.
Number of received words +1
C1
C2
CIO 0 to CIO 6143
W0 to W511
H0 to H511
A0 to A447
A448 to A959
T0000 to T4095
C0000 to C4095
D0 to D32767
@ D0 to @ D32767
*D0 to *D32767
Specified
0000 to 03E7
values only
hex
(0 to 999)
DR0 to DR15
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Section 3-23
S
R
A448 to
A959
#0000 (binary)
---