Omron CP - PROGRAMMING MANUAL 05-2007 Programming Manual page 772

Cp1h/cp1l cpu unit
Table of Contents

Advertisement

High-speed Counter/Pulse Output Instructions
0.00
Pulse frequency
Target frequency
50 kHz
Start frequency
200 Hz
PLS2(887) executed.
3-20-8 ACCELERATION CONTROL: ACC(888)
Purpose
Ladder Symbol
Variations
Applicable Program Areas
Operands
@PLS2
#0000
#0000
D100
D110
100,000 pulses
ACC(888) outputs pulses to the specified output port at the specified fre-
quency using the specified acceleration and deceleration rate. (Acceleration
rate is the same as the deceleration rate.) Either independent mode position-
ing or constant mode speed control is possible. For positioning, ACC(888) is
used in combination with PULS(886). ACC(888) can also be executed during
pulse output to change the target frequency or acceleration/deceleration rate,
enabling smooth (sloped) speed changes.
ACC(888)
P
P: Port specifier
M
M: Output mode
S
S: First word of settings table
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Block program areas
OK
OK
P: Port Specifier
The port specifier specifies the port where the pulses will be output.
P
0000 hex
Pulse output 0
0001 hex
Pulse output 1
0002 hex
Pulse output 2 (CP1H only)
0003 hex
Pulse output 3 (CP1H only)
0020 hex
Inverter positioning 0 (CP1L only)
0021 hex
Inverter positioning 1 (CP1L only)
D100
01F4
Acceleration rate: 500 Hz/4 ms
D101
Deceleration rate: 250 Hz/4 ms
00FA
D102
C350
Target frequency: 50 kHz
D103
0000
D104
86A0
Pulse output amount: 100,000 pulses
D105
0001
D110
00C8
Start frequency: 200 Hz
D111
0000
Time
Step program areas
Subroutines
OK
Port
Section 3-20
ACC(888)
@ACC(888)
Not supported
Interrupt tasks
OK
739