Fixing temperature control

Standby Temperature Control
This is a control to pre-heat the Fixing Assembly to reduce time to start printing.
• Flying Start
Print Temperature Control
This is a control to increase fixing temperature to the target level and keep it during printing.
• Startup (initial rotation) temperature control
• Print temperature control
• Paper interval temperature control
Down Sequence Control
This is a control to prevent fixing failure due to temperature increase at the edge or temperature decrease. Productivity
(throughput) decreases.
• Down Sequence due to Cartridge Temperature Rise
Related error codes
• E000-0001
Error in temperature rising of Fixing Assembly
• E001-0001
Fixing Assembly: Abnormally high temperature 1
• E001-0002
Fixing Assembly: Abnormally high temperature 2
• E001-0004
Fixing Assembly: Abnormally high temperature 3
• E003-0001
Fixing Assembly: Abnormally low temperature 1