Canon imageRUNNER ADVANCE 715iF III Series Service Manual page 310

Hide thumbs Also See for imageRUNNER ADVANCE 715iF III Series:
Table of Contents

Advertisement

E531-8002-02
Detection Description
Remedy
E540-8001-02
Detection Description
Remedy
E540-8002-02
Detection Description
Remedy
E540-8003-02
Detection Description
Remedy
E551-8001-02
Detection Description
Remedy
E568-8001-02
Detection Description
Remedy
Staple failure
The Staple Unit does not return to the HP within the specified period of time from the operation
start of the Staple Motor.
[Related parts]
- Jogger Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
Bin 1 Upper Limit Detection error
The Bin 1 Upper Limit Sensor does not react within the specified period of time after start of lift-
up.
[Related parts]
- Delivery Lifter Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
Bin 1 Lower Limit Detection error
The Bin 1 Lower Limit Sensor does not react even after the specified period of time after start of
lift-up.
[Related parts]
- Delivery Lifter Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
Bin 1 Lifter Sensor failure
Both the Bin 1 Upper Limit Sensor and the Bin 1 Lower Limit Sensor detected ON during tray
initialization.
[Related parts]
- Delivery Lifter Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
Finisher Fan failure
Finisher Fan Lock is detected.
[Related parts]
- Jogger Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
Stack Delivery Roller disengagement failure
When Y Alignment Motor is operated, the Stack Delivery Roller HP Sensor does not change.
[Related parts]
- Upper Feed Unit
- Finisher Controller PCB
- Harness between the Finisher Controller PCB and the DC Controller PCB
- DC Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
299
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents