2. Keep pressing the numeric keys (for approx. 20 seconds) until the following screen appears on the Control Panel.
NOTE:
When this tool is not installed correctly, the regular Startup screen is displayed.
In this case, perform the following remedy.
Turn OFF the Main Power Switch again, and execute steps 1 and 2 shown above.
If this tool still does not boot, it means that BCT (Box Checker Test) is deleted, so install BCT.
If BCT is not installed correctly, "- - . - -" is displayed in Service Mode (BCT) in the host machine.
• COPIER > DISPLAY > VERSION > BCT

Diagnosis Result

Diagnosis Time
Diagnosis is completed in approx. 3 minutes.
The result is displayed on the Control Panel.
When the diagnosis result is normal
When an error is detected by diagnosis
Detailed information is displayed under the judgment result. In detailed information, the name of the test where the error was
detected is displayed.
===============================================
BOX Checker Ver 0. 58
SCENARIO-1 Processing BoxMode check start. . .
----------------------------------------------------------------------------------
SN-1 IA-DDR2 SDRAM check start. . .
260