COPIER (Service mode for printer) > ADJUST (Adjustment mode) > ADJ-XY
ADJ-X-MG
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
ADJY-DF2
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
■ CCD
COPIER (Service mode for printer) > ADJUST (Adjustment mode) > CCD
W-PLT-X
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Amount of Change per
Unit
Fine adj img ratio: book mode, vert scan
To make a fine adjustment of image magnification ratio in vertical scanning direction at copyboard
reading.
As the value is changed by 1, the image magnification ratio is changed by 0.01%.
+: Reduce
-: Enlarge
When clearing the Reader-related RAM data/replacing the SATA Flash PCB, enter the value of
the service label on the reader.
When clearing the Reader-related RAM data/replacing the SATA Flash PCB
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-200 to 200
%
0
0.01
Adj read start pstn:DADF,back,horz scan
To adjust the back side image reading start position in horizontal scanning direction at DADF
reading.
As the value is incremented by 1, the image position is moved to the rear side by 0.1 mm.
When clearing the Reader-related RAM data/replacing the SATA Flash PCB, enter the value of
the service label on the reader.
When clearing the Reader-related RAM data/replacing the SATA Flash PCB
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-15 to 15
mm
0
0.1
Stdrd White Plt white lvl data (X) entry
To enter the white level data (X) for the Standard White Plate.
When clearing the Reader-related RAM data/replacing the SATA Flash PCB/replacing the
Copyboard Glass, enter the value of barcode label which is affixed on the glass.
- When clearing the Reader-related RAM data/replacing the SATA Flash PCB
- When replacing the Copyboard Glass
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
7000 to 9999
8273
COPIER> ADJUST> CCD> W-PLT-Y/Z