Lenovo Flex System x440 Compute Node Installation And Service Manual page 953

Table of Contents

Advertisement

Step 2.
Make sure that the microprocessor socket release levers are in the open position.
Step 3.
Align the microprocessor-retention assembly on the system board.
Attention:
1. Do not allow the microprocessor-retention assembly to touch the microprocessor socket.
Doing so might result in permanent damage to the system board.
2. Do not touch the contacts in the microprocessor socket. Touching these contacts might result
in permanent damage to the system board.
Step 4.
Using a T20 Torx screwdriver, install the four screws to secure the microprocessor-retention
assembly.
Step 5.
Install the heat-sink key on the microprocessor retention assemblies.
Step 6.
If necessary, install the microprocessor and heat sink (see
sink" on page
After you install the microprocessor-retention assembly, complete the following steps:
1. Install the cover onto the compute node (see
instructions).
2. Install the compute node into the chassis (see
instructions).
932).
Chapter 7
"Installing a microprocessor and heat
"Installing the compute node cover" on page 890
"Installing a compute node in a chassis" on page 881
.
Installing, removing, and replacing compute node components
for
for
943