Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the chassis.
– If the chassis successfully powers on, complete the following steps:
a. Check the
compatible with the chassis.
b. Inspect the previously installed components for physical damage.
– If the chassis does not successfully power on or if this is not the first occurrence of this
problem, replace the I/O expansion adapter.
• 80070217-2c03ffff : Sensor Mezz Exp 3 Fault has transitioned to critical from a less severe state.
The I/O expansion adapter in I/O expansion connector 3 has reported a fault.
May also be shown as 800702172c03ffff or 0x800702172c03ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the chassis.
– If the chassis successfully powers on, complete the following steps:
a. Check the
compatible with the chassis.
b. Inspect the previously installed components for physical damage.
– If the chassis does not successfully power on or if this is not the first occurrence of this
problem, replace the I/O expansion adapter.
• 80070217-2c04ffff : Sensor Mezz Exp 4 Fault has transitioned to critical from a less severe state.
The I/O expansion adapter in I/O expansion connector 4 has reported a fault.
May also be shown as 800702172c04ffff or 0x800702172c04ffff
Severity
Error
Serviceable
Yes
ServerProven website
to make sure that recently installed components are
ServerProven website
to make sure that recently installed components are
.
Chapter 6
Troubleshooting