• 80070217-2c01ffff : Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state.
The I/O expansion adapter in I/O expansion connector 1 has reported a fault.
May also be shown as 800702172c01ffff or 0x800702172c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the chassis.
– If the chassis successfully powers on, complete the following steps:
a. Check the
compatible with the chassis.
b. Inspect the previously installed components for physical damage.
– If the chassis does not successfully power on or if this is not the first occurrence of this
problem, replace the I/O expansion adapter.
• 80070217-2c02ffff : Sensor Mezz Exp 2 Fault has transitioned to critical from a less severe state.
The I/O expansion adapter in I/O expansion connector 2 has reported a fault.
May also be shown as 800702172c02ffff or 0x800702172c02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
306
ServerProven website
to make sure that recently installed components are