Finding the UEFI diagnostic code
• 806f030c-2581ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Memory error discovered during boot..(not a runtime error).
May also be shown as 806f030c2581ffff or 0x806f030c2581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
Related links
Finding the UEFI diagnostic code
• 806f030d-0400ffff : Hot Spare enabled for [ComputerSystemElementName].
A hot spare is available.
May also be shown as 806f030d0400ffff or 0x806f030d0400ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0170
User Response
Information only; no action required.
• 806f030d-0401ffff : Hot Spare enabled for [ComputerSystemElementName].
.