• 80010901-3702ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
The inlet 2 temperature has exceeded its specified threshold. The compute node has attempted a soft
shutdown.
May also be shown as 800109013702ffff or 0x800109013702ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 80010902-0701ffff : Sensor [NumericSensorElementName] has detected high voltage.
A voltage has exceeded its specified threshold.
May also be shown as 800109020701ffff or 0x800109020701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0494
User Response
Use one of the following procedures:
– If the specified sensor is Planar 3.3V or Planar 5V, replace the system board.
Lenovo Flex System x440 Compute NodeInstallation and Service Guide