Lenovo Flex System x440 Compute Node Installation And Service Manual page 395

Table of Contents

Advertisement

Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
1. Check the connections of the SAS cable between the disk and the backplane
2. (Trained service personnel only).
• 806f011b-1f04ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error.
The SAS cable connections between the SAS backplane 2 and the system board are not complete.
May also be shown as 806f011b1f04ffff or 0x806f011b1f04ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
1. Check the connections of the SAS cable between the disk and the backplane
2. (Trained service personnel only).
• 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by IPMI Watchdog.
The IPMI watchdog timer has expired. The compute node has restarted.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
.
Chapter 6