RAID volume 1 is functioning normally
May also be shown as 8007000d0b01ffff or 0x8007000d0b01ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0518
User Response
Information Only; no action required.
• 80070101-030101ff : Sensor CPU 1 Overtemp has transitioned from normal to non-critical state.
The microprocessor 1 temperature has risen above its specified threshold.
May also be shown as 80070101030101ff or 0x80070101030101ff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 80070101-030102ff : Sensor CPU 1 Overtemp has transitioned from normal to non-critical state.
The microprocessor 1 temperature has risen above its specified threshold.
May also be shown as 80070101030102ff or 0x80070101030102ff