Lenovo Flex System x440 Compute Node Installation And Service Manual page 225

Table of Contents

Advertisement

Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0029
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
6. Update the IMM firmware. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code.
Related links
Installing the LAN over USB Linux device driver
Installing the LAN over USB Windows device driver
• 4000001e-00000000 : Running the backup Management Controller [arg1] main application.
The IMM was unable to run the primary IMM image and has resorted to running the backup image.
May also be shown as 4000001e00000000 or 0x4000001e00000000
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0030
User Response
Update the IMM firmware. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
Related links
Updating firmware and device drivers
IBM Flex System and IBM PureFlex Firmware Updates Best Practices
• 4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the
correct firmware. The Management Controller is unable to match its firmware to the server.
.
Chapter 6
Troubleshooting
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

71672590

Table of Contents