4. If the problem remains, contact your technical-support representative.
Related links
Lenovo Support website
Latest level of DSA
• 217-900-000 : HDD Test Failed
HDD Test Failed. The hard drive self-test detected a failure.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.
Related links
Lenovo Support website
Latest level of DSA
DSA LSI hard drive test results
The following messages can result when you run the LSI hard drive test.
Test results for the DSA LSI hard drive test
The following messages can result when you run the DSA LSI hard drive test.
• 407-000-000 : LSIESG:DiskDefaultDiagnostic Test Passed
The test passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
• 407-800-000 : LSIESG:DiskDefaultDiagnostic Test Aborted