Chapter 5 View

Table 14 Status: Hardware Status

LABEL
Device Name
Device IP
Fan RPM
(RPM)
Index
Current
Max
Min
Threshold
Status
Voltage (V)
Index
Current
Max
Min
Threshold
Status
Temperature
Celsius
Fahrenheit
Index
Current
Max
Min
Threshold
Status
Polling
Close
58
DESCRIPTION
This field displays the descriptive name of a device.
This field displays the IP address of a device
A properly functioning fan is an essential component (along with a sufficiently
ventilated, cool operating environment) in order for the device to stay within the
temperature threshold. Each fan has a sensor that is capable of detecting and
reporting if the fan speed falls below the threshold shown.
This field displays the fan number.
This field displays this fan's current speed in Revolutions Per Minute (RPM).
This field displays this fan's maximum speed recorded in Revolutions Per Minute
(RPM).
This field displays this fan's minimum speed recorded in Revolutions Per Minute
(RPM).
This field displays the minimum speed at which a normal fan should work.
NORMAL indicates that this fan is functioning above the minimum speed. ERROR
indicates that this fan is functioning below the minimum speed.
The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range.
This field displays the first voltage sensor number.
This is the current voltage reading in volts.
This field displays the maximum voltage recorded at this sensor in volts.
This field displays the minimum voltage recorded at this sensor in volts.
This field displays the minimum voltage percentage at which the switch should work.
NORMAL indicates that the voltage is within an acceptable operating range at this
point; otherwise ERROR is displayed. ABSENT indicates that there is no power
reading at a sensor(s).
The switch has temperature sensors that are capable of detecting and reporting if
the temperature rises above the threshold. You may choose the temperature unit (in
degrees Celsius or Fahrenheit).
Select this option to display the temperature in degrees Centigrade.
Select this option to display the temperature in degrees Fahrenheit.
This field displays the temperature sensor number.
This shows the current temperature at this sensor.
This field displays the maximum temperature recorded at this sensor.
This field displays the minimum temperature recorded at this sensor.
This field displays the upper temperature limit at this sensor.
This field displays NORMAL for temperatures below the threshold and ERROR for
those above.
The text box displays how often (in seconds) this screen refreshes. You may change
the refresh interval by typing a new number in the text box and then clicking the
Apply button.
Click Close to close the screen.