14.5 GARP Timer

Switches join VLANs by making a declaration. A declaration is made by issuing a Join
message using GARP. Declarations are withdrawn by issuing a Leave message. A Leave All
message terminates all registrations. GARP timers set declaration timeout values. See the
chapter on VLAN setup for more background information.
1 In the Device Panel list, select a device and then right-click.
2 Click Configuration > Switch Configuration > Switch Setup.
3 Select the GARP Timer check box and then click Apply.
4 Click Configuration > Switch Configuration > GARP Timer to display the following
screen.

Figure 104 Switch Configuration: GARP Timer

The following table describes the labels in this screen.

Table 70 Switch Configuration: GARP Timer

LABEL
Join Timer
Leave Timer
Leave All Timer Leave All Timer sets the duration of the Leave All Period timer for GVRP in
Apply
NetAtlas Workgroup User's Guide
DESCRIPTION
Join Timer sets the duration of the join period timer for GVRP in milliseconds. Each
port has a join period timer. The allowed join time range is between 10 and 6553
centiseconds; the default is 20 centiseconds. See the chapter on VLAN setup for
more background information.
Leave Timer sets the duration of the leave period timer for GVRP in milliseconds.
Each port has a single leave period timer. Leave time must be at least two times
larger than Join Timer; the default is 60 centiseconds.
milliseconds. Each port has a single Leave All Period timer. Leave All Timer must be
larger than Leave Timer; the default is 1000 centiseconds.
Click Apply to save your changes.