■[F 0] Switch output specification switchover/setting mode switchover functions
●Setting of switch output NPN or PNP specification changeover
The specification can be changed to NPN or PNP output in accordance with the configuration of your
equipment.
<Example> D-MH1BP: PNP output
: It is a common setting for OUT1 and OUT2.
 The default value varies depending on the part No.
●Setting of switch output N.O. or N.C. specification changeover
The switch output specification can be changed to normally open (N.O. type) or normally closed (N.C.
type).
: It is a common setting for OUT1 and OUT2.
•Output operation
Analogue value
Within SP1 operating range
Within SP2 operating range
Within SP3 operating range
Other than the above.
: Only in 3 setting mode
●Setting of analogue display inversion
The displayed analogue voltage can be inverted at 3 V as the centre. This setting can be used for
applications such as making the display consistent when the polarity of magnets is not uniform.
<Example>
Displayed analogue value: 4316 [mV] ⇒ 1684 [mV] (Inverted)
The following values will also be inverted in conjunction.
•The set value of output points SP1 to SP3
•Peak or bottom measurement indicated value
N.O.
OUT1 (LED)
ON
OFF
ON
OFF
-38-
OUT2 (LED)
OUT1 (LED)
OFF
OFF
ON
ON
ON
OFF
OFF
ON
N.C.
OUT2 (LED)
ON
OFF
OFF
ON
No.D-※S-OMA1021