●Changing the output setting mode
The 2 setting mode and 3 setting mode can be changed.
•2 setting mode
In this mode, two points, SP1 and SP2, can be set.
The operating range for each of SP1 and SP2 may be overlapping.
Analogue value
Within SP1 operating range
Within SP2 operating range
SP1 and SP2 overlapping range
Other than the above.
•3 setting mode (Initial value)
In this mode, three points, SP1, SP2 and SP3, can be set.
The operating range for each of the points cannot be overlapping.
Analogue value
Within SP1 operating range
Within SP2 operating range
Within SP3 operating range
Other than the above.
: If the output setting mode is changed, the set values for output points (SP1 to SP3) will be cleared. Set them again.
N.O.
OUT1 (LED)
OUT2 (LED)
ON
OFF
OFF
ON
ON
ON
OFF
OFF
N.O.
OUT1 (LED)
OUT2 (LED)
ON
OFF
OFF
ON
ON
ON
OFF
OFF
-39-
N.C.
OUT1 (LED)
OUT2 (LED)
OFF
ON
ON
OFF
OFF
OFF
ON
ON
N.C.
OUT1 (LED)
OUT2 (LED)
OFF
ON
ON
OFF
OFF
OFF
ON
ON
No.D-※S-OMA1021