○Connection between the analogue auto switch and the sensor monitor
●Prepare the analogue ASW cable as shown in the figure below.
Sensor connector compliance table
SMC product No. (1 pc.)
ZS-28-C
ZS-28-CA-2
●Do not cut the insulator.
●Insert connectors with the marked sensor connector numbers and the corresponding cable core colours
as shown in the table below, to the end.
Connector marking No.
1
2
3
4
●Check the connector Nos. and core colours and that the cables are inserted to the end, and temporarily
connect them by pushing down part A by hand.
●Hold around the centre of part A and push it straight into connector enclosure using pliers, etc.
●The sensor connector cannot be used again after it has been pressure welded once.
If the core wire orders were mistaken or inserting the cables failed, use a new connector.
●If the sensor is not connected correctly, "LLL" may be displayed on the sensor monitor.
Conductor cross sectional area
2
(mm
)
0.14 to 0.2
0.1 to 0.5
Cable core colour
Brown (DC (+))
Not connected
Blue (DC (−))
Black (OUT: 1 to 5 V)
-19-
Outside diameter (O.D.)
(mm)
0.8 to 1.0
0.9 to 1.0
Colour of cover
Red