Analogue auto switch and display sensor monitor
Table of Contents

Advertisement

Setting of analogue display inversion
The analogue voltage indicated value can be inverted at 3 [V] as the centre.
: If the SP1 to SP3 set values have already been set, they will also be inverted in conjunction.
Press the UP or DOWN button to select the switch output specification.
Press the SET button to save the setting.
Setting of output setting mode
The 2 setting mode and 3 setting mode can be selected.
•2 setting mode
Output terminal
Output point
OUT1
SP1
ON
SP2
OFF
The relationship between the output terminals
and output points
•The two points, SP1 and SP2, can be set.
•The operating range may be overlapping.
Press the UP or DOWN button to select the switch output specification.
Press the SET button to save the setting.
[F 0] Setup of the switch output specification and setting mode functions completed
Perform the setting with the 3 step setting mode, simple setting mode and function selection mode.
Moves to the setting of output setting mode.
•3 setting mode
Output point
OUT2
SP1
OFF
ON
SP2
SP3
The relationship between the output terminals
and output points
•The three points, SP1, SP2, and SP3, can be set.
•The operating range may not be overlapping.
Returns to function selection mode.
Press the SET button for 2 seconds or longer.
Measurement mode
(Initial setting completed)
-33-
Output terminal
OUT1
OUT2
ON
OFF
OFF
ON
ON
ON
No.D-※S-OMA1021