■[F 1] SP1 setting
When the analogue voltage enters the operating range of SP1, the output turns ON.
By the factory default settings, the display colour turns green when the SP1 output is ON and red when the
SP1 output is OFF.
<How to operate>
Press the UP or DOWN button in function selection mode to display [F 1].
Setting of the output point (SP1)
Press the UP or DOWN button to adjust the set value.
The snap shot function can be used. (Refer to page 59)
(You can make minor adjustments with the UP or DOWN button after
setting by the snap shot function).
The set value can be deleted by pressing the SET and DOWN buttons
simultaneously for 1 second or longer.
Settable range: 800 to 5200
Press the SET button to save the setting.
Setting of the ON width (W_1)
Press the UP or DOWN button to adjust the set value.
Keep pressing the button to change it continuously.
(A long press of the button increases the change amount)
Settable range: 0 to 2200
Press the SET button to save the setting.
Setting of the hysteresis (H_1)
Press the UP or DOWN button to adjust the set value.
Keep pressing the button to change it continuously.
(A long press of the button increases the change amount)
Settable range: 0 to 2200
Press the SET button to save the setting.
Setting of the delay time (dt)
Press the UP or DOWN button to adjust the set value.
Keep pressing the button to change it continuously.
(A long press of the button increases the change amount)
: It is a common setting for SP1 to SP3.
Press the SET button to save the setting.
Press the SET button.
-41-
Moves to the setting of output point (SP1).
Moves to the setting of ON width (W_1).
Moves to setting of hysteresis (H_1).
Moves to the setting of delay time (dt).
Moves to the setting of display color (CoL).
No.D-※S-OMA1021