○Display sensor monitor
Model
Applicable sensor
Rated pressure range
Display and settable range
Display and minimum set unit
Power supply voltage
Current consumption
Display accuracy
Repeatability
Temperature characteristics
Output specification
Output mode
Switch operation
Maximum load current
Maximum applied voltage
(NPN only)
Internal voltage drop
(Residual voltage)
1
Delay time
Hysteresis
Protection
Input type
Number of inputs
Connection method
Protection
Display method
Number of displays
Display colour
2 3
Digital filter
Protection
Withstand voltage
Insulation resistance
Operating temperature range
Operating humidity range
Standards
Product
Lead wire with connector
1: Value without a digital filter (at 0 ms)
2: It is 90% response time in relation to the step input.
3: Display, switch output and analogue response time are affected.
4: We are endeavoring to improve product quality. However, any products with tiny scratches or smears on the appearance or display
color or accuracy variation which do not affect the performance are verified as conforming products.
1000 to 5000 [mV]
12 to 24 VDC ±10%, ripple max. 10% p-p (with polarity protection)
±20 mV ±1 digit (Ambient temperature: Constant at 25
±20 mV (25 °C standard)
Select from NPN open collector 2 output or PNP open collector 2 output
Select from 2 setting mode or 3 setting mode
Select from normal output or reversed output
NPN: 1 V or less (At a load current of 80 mA)
PNP: 1.5 V or less (At a load current of 80 mA)
1.5 ms or less (Anti-chattering function: can be set to 0.00 to 5.00 sec.)
(Smallest settable increment: 0.01 sec.)
Variable between 0 to 2200 (Initial value: 20 mV)
Over current protection
Voltage input: 1 to 5 VDC (Input impedance: 1 MΩ)
Connector (e-CON)
Over voltage protection (up to a voltage of 26.4 V)
3 (1 main display and 2 sub displays)
Main display: red or green; Sub display: orange
0, 10, 50, 100, 500, 1000, 5000 ms
1000 VAC for 1 minute between terminals and housing
50 MΩ or more between terminals and housing (with 500 VDC megger)
During operation: 0 to 50
(No condensation or freezing)
During operation and storage: 35 to 85%RH (No condensation)
CE/UKCA marked
25 g (without the power supply/output connection lead wires)
39 g (Lead wire with connector: ZS-46-5L)
-72-
D-MH1B#
D-MH1AD(V)#
800 to 5200 [mV]
2 [mV]
35 mA or less
±4 mV ±1 digits
80 mA
30 VDC
1 input
LCD
IP40
o
C, During storage: -10 to 60
o
C)
o
C
No.D-※S-OMA1021