Simple Setting Mode - SMC Networks D-MH1AD Series Operation Manual

Analogue auto switch and display sensor monitor
Table of Contents

Advertisement

Simple Setting Mode

<How to operate>
"Simple setting mode"
In the simple setting mode, the set value (SP1 to SP3
checking the current voltage current value (main display).
: The setting is possible only in 3 setting mode.
(1) Press the SET button for 1 second or longer but less than 3 seconds in measurement mode. [SEt] is
displayed on the main display.
Release the button while [SEt] is showing on the display. The main display will show the current voltage
value and the left sub display will show [SP1]. The set value will be flashing on the right sub display.
(2) Change the set value by pressing the UP or DOWN button, and press the SET button to set the value.
Then, the setting moves to [SP2] setting. (The snap shot function can be used. (Refer to page 59))
(3) Set [SP2] in the same manner as for [SP1]. When 3 setting mode is selected, the setting moves to the
[SP3] setting after finishing the [SP2] setting. Press the SET button to set the value. Then, the setting
moves to the delay time of the switch output.
(4) Press the UP or DOWN button to select the switch output delay time.
Press the UP button once to increment the value or press and hold it to continuously increment the
value.
(A long press of the button increases the increment.)
Settable range: 0.00 [sec.] to 5.00 [sec.] (0.01 [sec.] increment)
(5) Press the SET button to set the value and the setting returns to the [SP1] setting again. Press the SET
button for 2 seconds or longer in one of the settings screens to complete the setting and return to
measurement mode.
: Each of the selected items (1) to (4) is enabled after the SET button is pressed.
) and the delay time (dt) can be changed while