Sony DVS-9000 User Manual page 591

Production switcher system
Hide thumbs Also See for DVS-9000:
Table of Contents

Advertisement

Icon
Title
Error
File Frame
Memory
File Open
Status
GPI Input
590
Error Messages
Message
This operation is cancelled,
because the register is locked.
Please change the register
status to be unlocked first.
The file was not able to be
read.
It was not possible to make a
file.
Failed...
The Source and the target are
the same directory.
Please change the source or
the target directory.
Some requests are skipped.
Following operation is not
permitted.
— Loading that will cause
duplicate register name.
ERROR (01)
ERROR (02)
ERROR (FF): No target device
has been assigned
Please set Target.
Please set Trigger Type.
Please set Reg No.
Please set Aux Bus No.
Please set Src No.
Please set Pulse Width.
Please set Pulse Timing.
Description
6211.1: Effect >Master Timeline >Store >Edit
6311.1: Snapshot >Master Snapshot >Store
>Edit
6411.1: Shotbox >Register >Store/Recall >Edit
In the above menu, an attempt was made to
assign to a register that is locked. Unlock the
register before carrying out the assignment.
7142.1: File >Shotbox, Macro >File Edit
In the above menu, [Off Line Edit] was pressed
but the selected file could not be read.
Select the file again, and press [Off Line Edit]
once more.
7142.3: File >Shotbox, Macro >File Edit >Off
Line Edit
In the above menu, when storing, the file could
not be written.
Try the store once more.
7162: File >All, External File >Import/Export
In the above menu, importing a file failed.
Check the format of the original file, and try
again.
7172: File >Configure >Unit ID Copy
In the above menu, the same directory and ID
were selected for source and target.
Select a different directory and ID.
7151: File >Frame Memory
7162: File >All, External File >Import/Export
In the above menu, an attempt was made to
load a file of a name already existing in the
register.
533X: Device >DDR/VTR menu
When an error is returned from the DDR/VTR,
one of these messages appears, depending on
the error number.
Use Menu7355:Engineering Setup >DCU
>Serial Port Assign or
Menu7325.4:Engineering Setup >Panel
>Device Interface >Serial Port Assign to check
the device settings.
7325.1/2: Engineering Setup >Panel >Device
Interface >GPI Input
7344.1/2: Engineering Setup >DME >Device
Interface >DME1 GPI Input
7344.5/6: Engineering Setup >DME >Device
Interface >DME2 GPI Input
7352/7352.1: Engineering Setup >DCU >GPI
Input Assign
In the above menus, when making a setting, a
parameter setting value was incorrect. Check
the settings, and try again.