13. Program Support Functions
(5) When the start point designated by G115 is not on the next block movement path of the other
part system, the own system starts once the other part system has reached all of the start point
axis coordinates.
Example:
X
Z
(6) The following operation is executed by parameters (base specification parameter #1229
set01/bit5) when the start point cannot be determined by the next block movement of the other
system.
(a) When the parameter is ON
Operation waits until the start point is reached by the movement in the next and
subsequent blocks.
Own part system
Other part system
(b) When the parameter is OFF
The own part system starts upon completion of the next block movement.
Own part system
Other part system
(7) The waiting status continues when the G115 command has been duplicated between part
systems.
(8) Designate the start point using the workpiece coordinates of the other part system.
(9) Program error "P33" occurs when the G115 command is issued for 3 part systems.
(10) The single block stop function does not apply for the G115 block.
(11) When the G115 command is issued continuously in 2 or more blocks, the block in which it was
issued last will be valid.
(12) A program error (P32) will occur if an address other than an axis is designated in G115
command block.
13.14 Start Point Designation Synchronizing (Type 1)
X also has passed
Z has passed
: Movement
272
: Command point
Waiting
!G115
!
!G115
!
: Actual start point