Appendix 2. Program Error
Error No.
P292
SETVN SNT. ERR
There is an error in the SETVN
when the variable name setting was made.
P293
DO-END EXCESS
The number of
WHILE conditional DO -END
has exceeded 27.
P294
DO-END MMC.
The DO's and END's are not paired off
properly.
P295
WHILE/GOTO TPE
There is a WHILE or GOTO statement on
the tape during tape operation.
P296
NO MACRO ADDR.
A required address has not been specified
in the user macro.
P297
ADR-A ERR
The user macro does not use address A as
a variable.
P298
PTR OP (MACRO)
User macro G200, G201, or G202 was
specified during tape or MDI operation.
P300
VAR. NAME ERROR
The variable names have not been
commanded properly.
P301
VAR NAME DUPLI
The name of the variable has been
duplicated.
P360
NO PROG. MIRR
A mirror image (G50.1 or G51.1) command
has been issued though the programmable
mirror image specifications are not
provided.
P380
NO CORNER R/C
A command was issued for corner rounding
or corner chamfering though there are no
such specifications.
P381
NO ARC R/C SPC
Corner rounding or chamfering was
specified in the arc interpolation block
although corner chamfering/corner
rounding II is unsupported.
P382
CORNER NO MOVE
The block next to corner rounding/
chamfering is not a movement command.
Details
statement
s for DO-END
in the
statement
330
Remedy
• Review the program.
• The number of characters in the variable
name of the SETVN statement must be 7 or
less.
• Review the program and correct it so that the
number of the DO-END statement does not
exceed 27.
• Review the program and correct it so that the
DO and END are paired off properly.
• During tape operation, a program which
includes a WHILE or GOTO statement
cannot be executed and so the memory
operation mode is established instead.
• Review the program.
• Review the program.
• Review the program.
• Review the variable names in the program
and correct them.
• Correct the program so that the name is not
duplicated.
• Check the specifications.
• Check the specifications.
• Remove the corner rounding or chamfering
command from the program.
• Check the specifications.
• Replace the block succeeding the corner
rounding/chamfering command by movement
command block.