(5) Reference point return during mirror image
If the reference point return command (G28, G30) is executed during the mirror image, the
mirror image will be valid during the movement to the intermediate point, but will not be applied
on the movement to the reference point after the intermediate point.
(6) Return from zero point during mirror image
If the return command (G29) from the zero point is commanded during the mirror image, the
mirror will be applied on the intermediate point.
(7) The mirror image will not be applied on the G53 command.
Intermediate point when
mirror is applied
Path on which mirror
is applied
Mirror center
236
13.6 G command mirror image
Intermediate point
Programmed path